Connectors, including anchors and fasteners, installed in corrosive environments or exposed to corrosive materials, or chemicals, can be damaged possibly resulting in the reduction of load capacity. The selection of the proper connector coating can be a complicated task. Environments can vary greatly regionally and are also influenced by variables such as fertilizer, animal waste, and wet cycle durations. If an electrolyte is present, such as water, a metal will form an electric circuit with a dissimilar metal and galvanic corrosion can take place. Zinc is the metal used in the hot-dip galvanizing process due to its ability to sacrifice itself while protecting the base steel underneath. When the zinc and copper are in electrical contact with each other the copper will have a tendency to extract electrons from the highly reactive zinc at a greater rate, therefore corrosion will take place at a greater rate. That being the case it is impossible to prescribe a reasonable uniform solution which will serve all environments adequately.

In cooperation with the Environmental Protection Agency, chemical producers in the treated wood industry agreed to discontinue the use of Chromated Copper Arsenate (CCA) for most residential applications at the end of 2003. In place of CCA, treated wood suppliers use copper based alternative treatment chemicals such as Amine/Ammoniacal Copper Quat (ACQ-C, ACQ-D), and Copper Azole (CBA-A, CA-B). Sodium Borate (SBX, DOT) is used primarily in sill plate applications. Testing conducted by USP and others in the industry have concluded the ACQ and Copper Azole wood treatments are more corrosive to metals than traditionally used CCA treatments are.

Recently some wood preservative manufacturers have introduced new wood preservative formulations. These formulations include new micronized copper products as well as carbon based PTI wood preservatives. Testing by USP has found some of these formulations are less corrosive than ACQ and CA-B products, but not necessarily the same as untreated wood.

USP Structural Connectors currently offers four different corrosion resistant finishes to cover a range or corrosion performance:


Triple Zinc logo
Triple Zinc (TZ) – galvanizing provides a prefabrication coating of 1.85 (G-185) ounces of zinc per square foot of surface area measured in accordance with ASTM A 653.
Fastener: Hot-dip galvanized fasteners

Hot-Dip Galvanized (HDG) – coating provides an after-fabrication hot-dipped zinc coating. The coating thickness is dependent on the connector material, but generally ranges from 1.1 to 2.3 ounces of zinc per square foot of surface. Hot-dip products meet requirements set forth in ASTM A 123.
Fastener: Hot-dip galvanized fasteners

Gold Coat logo
Gold Coat (GC) - gold coat is a proprietary multi-layer protection system. It is comprised of an organic top coat barrier layer and a zinc layer placed over a steel substrate.
Fastener: Gold Coat fasteners

Stainless Steel (SS) – is the best option for corrosion protection. Quality stainless steel (316SS grade steel) is used to fabricate connectors. Although costs are higher, some applications may need the virtual corrosion proof quality of stainless steel.
Fastener: Stainless Steel fasteners


The coating recommendations listed below have been developed by reviewing both field service performance and accelerated corrosion testing results. While accelerated corrosion testing is a valuable tool to help predict relative performance, both the particular testing method used by the industry and the different wood treatment products tested are relatively new and there is little actual field service life data to correlate to the test results. In addition, actual service environments are much more complicated than accelerated tests. In accelerated tests influencing variables are typically minimized and manupulated to cause reactions to occur more quickly. Consequently, this may result in reactions which are not completely representative of actual service conditions. Because of this it is difficult to assign an expected service life to a given coating in an environment based on the results of accelerated testing.

USP Structural Connectors Coating Recommendations
AWPA Use
Category
Service
Conditions
Use
Environment
Example
Applications
Preservatives and
Retentions
6,7
Minimum Coating
Requirements
1,2,3,4
UC1 Interior construction, Above ground, Dry Continuously protected from weather or other sources of moisture General framing, interior construction Untreated G90
UC2 Interior construction, Above ground, Damp Protected from weather, but may be subject to sources of moisture Sill plates SBX-DOT, Organic

ACQ-D (0.25), CA-B (0.10), CA-C (0.06), MCQ (0.25), µCA-C (0.05)
Triple Zinc (G185)8,9
UC3A Exterior construction, Above ground, Rapid water runoff Exposed to all weather cycles, not exposed to prolonged wetting Exposed exterior beams or columns in an open, covered structure ACQ-D (0.25), MCQ (0.25), CA-B (0.10), CA-C (0.06), µCA-C (0.05), Organic Triple Zinc (G185) or USP Gold Coat
UC3B Exterior construction, Above ground, Poor water runoff Exposed to all weather cycles, including prolonged wetting Deck beams and joists ACQ-D (0.25), MCQ (0.25), CA-B (0.10), CA-C (0.06), µCA-C (0.05), Organic Triple Zinc (G185) or USP Gold Coat
UC4A Exterior construction, Ground contact, General use Ground contact or fresh water exposed to all weather cycles Deck posts ACQ-D (0.40), MCQ (0.40), CA-B (0.21), CA-C (0.15), µCA-C (0.14) Triple Zinc (G185) or USP Gold Coat5
UC4B Exterior construction, Ground contact, Critical structural Ground contact, fresh or salt water exposed to all weather cycles Permanent wood foundations, critical structural members ACQ-D (0.60), MCQ (0.60), CA-B (0.31), CA-C (0.25), µCA-C (0.23) Stainless Steel
Notes
1. G90 and G185 refer to galvanization requirements for ASTM A653 material.
2. Connectors galvanized to ASTM A123 may be used in place of either G90 or G185 coatings.
3. Other coating may be suitable for a given environment if the conditions are known and predictable.
4. For G90 or G185 connectors use fasteners galvanized per ASTM A153. For Gold Coat connectors use Gold Coat fasteners, and for stainless steel connectors use stainless steel fasteners.
5. If the enviroment has the potential to contain elements which may make it more corrosive, the use of stainless steel is recommended.
6. MCQ is a miconized copper treatment such as Micro Pro by Osmose. µCA-C is a dispersed copper treatment manufactured by Arch Treatment Technologies. Organic preservatives include L3 from Arch Treatment Technologiesand EcoLife II from Viance, LLC.
7. For wood treatments not shown contact USP or the wood preservative manufacturer for recommended coatings.
8. Testing by USP has found that in interior applications where the treated wood will remain relatively dry during its service life the use of G90 connectors with MCQ or µCA-C treated wood is appropriate.

The formulations used by wood preservative manufacturers are constantly changing and improving. USP Structural Connectors continues to test new wood treatments as they become available and will continue to update its recommendation as appropriate. Neither the 2006 International Residential Code or 2006 International Building Code specifically prescribe a recommended coating weight or type for connector products such as joist hangers, column caps, etc. In cases such as this we advise following the connector manufacturer's recommendations.

Corrosion Protection Guidelines:
  • USP recommends stainless steel connectors for the highest level of corrosion protection. As an economical alternative to stainless steel our new Gold Coat connectors are specifically designed for exterior application when in contact with preservative treated wood.
  • Triple Zinc G-185 connectors are available as an economical alternative for exterior applications which will provide a minimum level of protection.
  • The use of correct fastener with the connector is critical. Stainless steel connectors require stainless steel fasteners. For exterior applications, hot-dip galvanized fasteners (HDG) must be used with both Triple Zinc and Hot-dip Galvanized finishes. Gold Coat connectors require gold coat fasteners.
  • USP's zinc dichromate WS Wood Screws are not recommended for use with preservative or fire-retardant treated wood. Some wood screws are available in Gold Coat.
  • USP Structural Connectors clearly differentiates standard G90 connectors from the corrosion resistant connectors. Gold Coat connectors are distinguishable from other connectors because of their concealing color. Following are examples of our carton labels, bin cards for retail displays, and individual product labels.


Corrosion Resistant Products

Column/Post Bases
Column/Post Caps
Embedded Truss Anchors
Fasteners/Anchors
Framing Plates & Angles
Holdowns/Foundation Anchors
Hurricane/Seismic Anchors
Joist Hangers
Miscellaneous
Straps
Stud Plate Ties
Truss Hangers
Twist Straps
 
 

Fasteners/Anchors Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
8d (0.131") x 1-1/2 nail   NA11 NA11SS N8-GC
10d (0.148") x 1-1/2 nail   NA9D   N10-GC
16d (0.162") x 2-1/2 nail   NA16D    
20d (0.192") x 1-3/4 nail   NA21    
20d (0.192") x 2-1/2 nail   NA20D    
8d Common (0.131" x 2-1/2")       N8C-GC
10d Common (0.148" x 3")       N10C-GC
16d Common (0.162" x 3-1/2")       N16C-GC
1/4 X 1-1/2 Wood Screw       WS15-GC
1/4 x 2-1/2 nail   NA250    
1/4 x 3 nail   NA25    
AB126-HDG   AB126-HDG    
AB128-HDG   AB128-HDG    
AB1212-HDG   AB1212-HDG    
BP1   BP1-HDG    
BP12   BP12-HDG    
BP58   BP58-HDG    
BP78   BP78-HDG    
BP582   BP582-HDG    
BP583   BP583-HDG    
HBPS12   HBPS12-HDG    
HBPS34   HBPS34-HDG    
LBP12-TZ LBP12-TZ      
LBP34-TZ LBP34-TZ      
LBP58-TZ LBP58-TZ      
LBPS12-TZ LBPS12-TZ      
LBPS58-TZ LBPS58-TZ      
STB16   STB16-HDG    
STB20   STB20-HDG    
STB24   STB24-HDG    
STB28   STB28-HDG    
STB34   STB34-HDG    
STB36   STB36-HDG    
STBL16   STBL16-HDG    
STBL20   STBL20-HDG    
STBL24   STBL24-HDG    
STBL28   STBL28-HDG    
STBL34   STBL34-HDG    
THR125-HDG   THR125-HDG    
THR126-HDG   THR126-HDG    
THR128-HDG   THR128-HDG    
THR5816-HDG   THR5816-HDG    
Holdowns/Foundation Anchors Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
FA3 FA3-TZ      
HPA35   HPA35-HDG    
PA18 PA18-TZ      
PA23 PA23-TZ      
PA28 PA28-TZ      
PA35 PA35-TZ      
ST1 ST1-TZ      
ST2 ST2-TZ      
TA51 TA51-TZ      
TA71 TA71-TZ      
TDL5 TDL5-TZ      
TDL10 TDL10-TZ      
TDX2 TDX2-TZ TDX2-HDG    
TDX6   TDX6-HDG    
TDX8   TDX8-HDG    
Embedded Truss Anchors Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
HTA20 HTA20-TZ      
HTA24 HTA24-TZ      
TA20 TA20-TZ      
TA24 TA24-TZ      
Hurricane/Seismic Anchors Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
HHCP2 HHCP2-TZ      
LFTA6 LFTA6-TZ      
RT3A RT3A-TZ      
RT4 RT4-TZ   RT4-SS  
RT5 RT5-TZ   RT5-SS  
RT7 RT7-TZ
RT7-SS  
RT7A RT7A-TZ     RT7A-GC
RT10 RT10-TZ
RT10-SS  
RT15 RT15-TZ     RT15-GC
RT16 RT16-TZ   RT16-SS  
RT16-2 RT16-2TZ      
RT20 RT20-TZ      
Column/Post Bases Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
CBS44   CBS44-HDG    
CBS66   CBS66-HDG    
CBSQ44-TZ CBSQ44-TZ      
CBSQ46-TZ CBSQ46-TZ      
CBSQ66-TZ CBSQ66-TZ      
D44 D44-TZ      
D46 D46-TZ      
D66 D66-TZ      
EBG44 EBG44-TZ      
EPB4408   EPB4408-HDG    
KCB44   KCB44-HDG    
KCB46   KCB46-HDG    
KCB48   KCB48-HDG    
KCB66   KCB66-HDG    
KCB68   KCB68-HDG    
KCB88   KCB88-HDG    
KCB1010   KCB1010-HDG    
KCB1012   KCB1012-HDG    
PA44 PA44-TZ      
PA44E PA44E-TZ     PA44E-GC
PA46 PA46-TZ      
PA46E PA46E-TZ     PA46E-GC
PA66 PA66-TZ      
PA66E PA66E-TZ     PA66E-GC
PAU44 PAU44-TZ      
PAU46 PAU46-TZ      
PAU66 PAU66-TZ      
PAU88 PAU88-TZ      
PBC44-TZ PBC44-TZ      
PBC66-TZ PBC66-TZ      
WAS44 WAS44-TZ      
WAS46 WAS46-TZ      
WAS66 WAS66-TZ      
WE44 WE44-TZ      
WE46 WE46-TZ      
WE66 WE66-TZ      
Column/Post Caps Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
C44 C44-TZ      
C46 C46-TZ      
C66 C66-TZ      
EPCM4416 EPCM4416-TZ      
EPCM4616 EPCM4616-TZ      
KCC44   KCC44-HDG    
KCC46   KCC46-HDG    
KCC64   KCC64-HDG    
KCC66   KCC66-HDG    
KECC44   KECC44-HDG    
KECC46   KECC46-HDG    
KECC64   KECC64-HDG    
KECC66   KECC66-HDG    
PB44-6 PB44-6TZ     PB44-6GC
PB66-6 PB66-6TZ     PB66-6GC
PBES44 PBES44-TZ      
PBES66 PBES66-TZ      
PBS44 PBS44-TZ      
PBS66 PBS66-TZ      
PCM44 PCM44-TZ      
PCM4416 PCM4416-TZ      
PCM46 PCM46-TZ      
PCM4616 PCM4616-TZ      
PCM66 PCM66-TZ      
PCM6616 PCM6616-TZ      
Joist Hangers Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
HUS26 HUS26-TZ      
HUS28 HUS28-TZ      
HUS28-2IF HUS28-2IFTZ      
HUS210 HUS210-TZ      
HUS210-2IF HUS210-2IFTZ      
JUS24 JUS24-TZ   JUS24-SS JUS24-GC
JUS26 JUS26-TZ   JUS26-SS JUS26-GC
JUS26-2 JUS26-2TZ   JUS26-2SS JUS26-2GC
JUS28 JUS28-TZ   JUS28-SS JUS28-GC
JUS28-2 JUS28-2TZ      
JUS28-3 JUS28-3TZ      
JUS210 JUS210-TZ   JUS210-SS JUS210-GC
JUS210-2 JUS210-2TZ   JUS210-2SS JUS210-2GC
JUS210-3 JUS210-3TZ      
JUS44 JUS44-TZ      
JUS46 JUS46-TZ      
JUS48 JUS48-TZ      
JUS410 JUS410-TZ      
JUS414 JUS414-TZ      
LSSH15-TZ LSSH15-TZ      
LSSH210 LSSH210-TZ      
LSSH31 LSSH31-TZ      
SKH26R/L SKH26R/L-TZ     SKH26R/L-GC
SKH28R/L SKH28R/L-TZ      
SKH210R/L SKH210R/L-TZ     SKH210R/L-GC
Truss Hangers Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
MSH418 MSH418-TZ      
MSH422 MSH422-TZ      
THD210-2 THD210-2TZ      
Framing Plates & Angles Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
A3 A3-TZ      
AC5 AC5-TZ      
AC7 AC7-TZ     AC7-GC
AC9 AC9-TZ     AC9-GC
JA1 JA1-TZ      
MP3 MP3-TZ      
MP34 MP34-TZ   MP34-SS  
MP4F MP4F-TZ      
MP5 MP5-TZ      
MP7 MP7-TZ     MP7-GC
MP9 MP9-TZ     MP9-GC
MPA1 MPA1-TZ   MPA1-SS MPA1-GC
Stud Plate Ties Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
RSPT4 RSPT4-TZ      
RSPT6 RSPT6-TZ      
RSPT6-2 RSPT6-2TZ      
SPT4 SPT4-TZ      
SPT6 SPT6-TZ      
SPT22 SPT22-TZ      
SPT24 SPT24-TZ      
SPTH4 SPTH4-TZ      
SPTH6 SPTH6-TZ      
Straps Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
KRPS18 KRPS18-TZ      
KRPS22 KRPS22-TZ      
L6 L6-TZ     L6-GC
LSTA24     LSTA24-SS  
MSTA9 MSTA9-TZ      
MSTA12 MSTA12-TZ   MSTA12-SS  
MSTA15 MSTA15-TZ   MSTA15-SS  
MSTA18 MSTA18-TZ   MSTA18-SS  
MSTA21 MSTA21-TZ      
MSTA24 MSTA24-TZ      
MSTA30 MSTA30-TZ      
MSTA36 MSTA36-TZ      
PS218-HDG   PS218-HDG    
PS418-HDG   PS418-HDG    
PS720-HDG   PS720-HDG    
RS150 RS150-TZ      
RT24F RT24F-TZ      
T6 T6-TZ     T6-GC
Twist Straps Triple Zinc
(TZ)
Hot-Dip Galvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
LTW12 LTW12-TZ   LTW12-SS  
LTW18 LTW18-TZ   LTW18-SS  
LTW20     LTW20-SS  
MTW12 MTW12-TZ      
MTW16 MTW16-TZ      
MTW20 MTW20-TZ      
MTW30 MTW30-TZ      
RT24T RT24T-TZ      
Miscellaneous Triple Zinc
(TZ)
Hot-DipGalvanized
(HDG)
Stainless Steel
(SS)
Gold Coat
(GC)
ANJ44S   ANJ44S-HDG    
CSH-TZ CSH-TZ      
DC50-TZ DC50-TZ      
ERB24-TZ ERB24-TZ      
FB14-TZ FB14-TZ      
FB16-TZ FB16-TZ      
FB23-TZ FB23-TZ      
FC24-TZ FC24-TZ      
FRB24-TZ FRB24-TZ      
ICPL58 ICPL58-TZ      
ICPL516-TZ ICPL516-TZ      
PRT2 PRT2-TZ      
SCA9-TZ SCA9-TZ     SCA9-GC
SCA10-TZ SCA10-TZ     SCA10-GC
SDJT14-TZ SDJT14-TZ      
SDPT5-TZ SDPT5-TZ      
SDPT7-TZ SDPT7-TZ      
© Copyright 2006-2008
USP Structural Connectors
Privacy Policy
USP Products | About USP | Continuing Education | Industry Links | Literature Requests | Press Releases | Technical Resources | What's New | Catalogs | CAD Library | Comparison Guides | Contact Us | Literature Request | News

Designed, Produced and Hosted by BuildingOnline:
The Building Industry's Web Design and Marketing Agency.